General requirements applicable to all samples are followed by requirements specific to analysis type.

General Requirements for All Samples

Sampling Quality Control Data and Information:

  • Chain-of-Custody
  • Date and time each sample was taken
  • Map or diagram indicating sample locations
  • Any notable observations (color, clarity, texture, reaction with preservatives, etc.)
  • Trip blank (or field blank)
  • Equipment blank (rinsate blank)
  • Identity of field duplicates (a minimum of one duplicate for every 20 or fewer samples)
  • Sample for site specific MS/MSD

Laboratory Quality Control Data and Information:

  • Completed Chain-of-Custody
  • Date and time of receipt at the laboratory
  • Condition of samples upon receipt at the laboratory
  • Sample identification number or designation
  • Sample preparation, extraction, cleanup, or digestion method(s) and date(s)
  • Analytical method (name, number, and source) and date of analysis
  • Final analytical results
  • Case narrative (Includes deviations from standard analytical or preparatory procedure(s); quality control problems encountered--whether stemming from system, instrumentation, analyst error, or sample matrix; corrective measures taken; if corrective measures as called for in the method were not taken; results of corrective measures taken; etc.)

Top

Specific Requirements by Analysis Type

Organic Analyses
Volatile Organic Analysis (VOA) and Semivolatile Organic Analysis (SVOA)
by Gas Chromatography/Mass Spectrometry (GC/MS)

  • Method blank summary sheet with results, including detections
  • Detection/quantitation limit for each compound
  • Internal standards summary
  • Surrogate (System Monitoring Compound) results (concentration of surrogate spikes added, measured concentrations, and % Recoveries of all surrogates) for each sample
  • Matrix Spike/Matrix Spike Duplicate (MS/MSD) results (sample concentration for analyte, concentration of spike added, results, % Recovery for each compound, and Relative Percent Difference between MS and MSD for each compound)
  • Laboratory Control Sample results

Analysis of Volatile Organic Compounds and Semivolatile Organic Compounds by
Gas Chromatography (GC) Using Method-Specified Detectors (FID, PID, HECD, etc.) and Analysis of Semivolatile and Nonvolatile Organic compounds by High Performance Liquid Chromatography (HPLC)

  • Method of sample introduction (direct injection or purge-and-trap)
  • Detection/quantitation limit for each compound
  • Method blank summary
  • Surrogate recoveries for samples, blanks, and spikes
  • Matrix spike/matrix spike duplicate (MS/MSD) analysis or lab duplicates
  • Laboratory Control Sample results

Analysis of PCBs by Gas Chromatography (GC) with Electron Capture Detector (ECD) or Electrolytic Conductivity Detector (ELCD or HECD)

  • Method blank summary
  • Detection/quantitation limit for each compound (in each sample)
  • Surrogate recoveries for samples, blanks, and spikes
  • Matrix spike/matrix spike duplicate (MS/MSD) analysis or laboratory duplicates
  • Laboratory Control Sample results

Metals and General Chemistry Analyses
Total and Dissolved Metals by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP) or Atomic Absorption Spectroscopy (AA) and General Chemistry Analyses

  • Method/sample quantitation limits
  • Instrument detection limits
  • Blank results
  • Matrix spike (sample number of sample spiked, sample concentration for analyte, concentration of spike added, results and % Recovery)
  • Matrix spike duplicate or laboratory duplicate (results and Relative Percent Difference [RPD]; if matrix spike duplicate, also report %Recovery)
  • Laboratory control sample (QC standard or lab-fortified blank: results and %Recovery).

Top

Web Availability and Additional Information

If full QA/QC documentation is requested, the requirements can be found in Appendix 2 of the Risk Integrated System of Closure (RISC) Technical Guide, pages 8-11. The RISC Technical Guide is available on the IDEM Web site at: Top